Non Clog and Wastewater Pumps

Today, water treatment, its conservation, recycling & its reuse have assumed greater significance. Thus, the demand for pumping / treating waste water is going up steadily. The present methods are also more versatile & thus demand greater reliability as far as pumping needs are concerned. Darling Pumps, having worked effectively in this sector, can offer a reliable & effective wastewater pump manufacturer solution.

As we have been working in this sector for over 4 decades, we have made our pump designs more adaptable to challenges in this sector… not only in terms of capacities but also in terms of MOC’s & many significant add-on features.

Non-clog Series Pumps
Features
Impeller -Wear resistant SS impeller with wide passages that can pass solids up to 100mm.
Motor – Highly efficient dry motor with built -in protection against temperature rise.motor capable to withstand wide voltage fluctuations.
Shaft – Extra heavy duty SS Shaft.
Mechanical Seals -Dual Mechanical seal fitted in independent chambers, not exposed to pumpage liquid and devoide of discharge pressure.
Bearing– Heavy duty ball bearing used at top and bottom ends to balance adverse load.
Seal Guard Protection-Additional protection for machanical seal by seal guard.
Cable Sealing – Special leak proof cable sealing arrangement,to avoid ingress of water through cable.no need to open motor for changing cable.
Treashguard -Special arrangement to avoid builtup of solids above the impeller.
Applications
  • Municipal Waste, Raw & Un-Screened Sewage
  • Industrial Wastes & Effluents
  • Pharmaceutical, Textile & Tanning Plants
  • Municipal Sewer pumps
  • Effluent Treatment And Sewage Treatment Plants
  • Ro Reject / Desalination Projects
  • Chemical Handling Plants & Many More….
  • Private Pumping / Sewage Stations.
Non-clog Series Pumps
 Tech. Specifications*
Rating:Up to 300 HP
RPM:1450 /960
Frequency:50 HZ
Supply:Three phase- 415 V
Starting:DOL
Motor:Wet type / Dry type
Process Data
Liquid temperature:Max 40° C
Liquid Density:Max 1100 kg/m3
Suitable for liquid pH:6 to 8
Stainer Hole Size:Up to 100 mm
Materials*
Impeller:CA – 15, CF8, CF8M,various grades of Cl
Shaft:AISI-410, SS-304, SS-316
Difusser:Various grades of CI/ SS
Wear plate:Various grades of CI/ SS
Mech. SealSic  v/s Sic, Tc  v/s Tc
Non-clog Series Pumps
Pump ModelHP/KWRPMOUTLET / DN SIZESOLID PASSAGEMINIMUM SUBMERGENCE (Approx.)WIDTH / OUTER DIA (Approx.)HEIGHT (Approx.)Net Weight (In Kg) (Approx.)
4SR-03G/40+3.0/2.2144010040720405875125
4SC-03G/80+3.0/2.2144010080720405875125
4SR-03EH/18+3.0/2.214405018600460750115
4SR-05EH/18+5.0/3.714405018600460750120
4SR-05G/40+5.0/3.7144010040720405875130
4SC-05G/80+5.0/3.7144010080720405875130
4SR-07EH/18+7.5/5.514505018600460800180
4SR-07I/40+7.5/5.5145010040760465955205
4SC-07I/100+7.5/5.51450100100760465955205
4SP-07IL/20+7.5/5.5145010020690480890177
4SP-07ML/20+7.5/5.5145015020690520895187
4SP-10ML/20+10/7.5145015020690520895197
4SR-10F/40+10/7.514506540610480810137
4SR-10I/40+10/7.5145010040760465955242
4SC-10I/100+10/7.51450100100760465955242
4SC-10M/100+10/7.51450150100740590945242
4SR-15K/50+15/11145010050780580990267
4SC-15I/100+15/1114501001008204651025267
4SR-15F/40+15/1114506540675480880220
4SR-20K/50+20/151460100508605801065292
4SR-20J/35+20/151460100358506351055267
4SR-20M/100+20/1514601501008705901080295
4SR-25J/35+25/18.51460100358506351055295
4SR-25K/60+25/18.51460100608705801075295
4SR-25M/100+25/18.514601501008705901080295
4SR-25N/100+25/18.514602001009106701120295
4SR-30J/20+30/221460100209356351140320
4SR-30K/60+30/221460100609555801160320
4SR-30M/100+30/2214601501009605901165320
4SR-30N/100+30/22146020010010006701205330
4SR-40N/100+40/30146020010010006701205410
4SR-40M/50+40/301460150508707301075400
4SR-50M/50+50/371460150509907301375658
4SR-50N/100+50/37146020010010156701505510
4SR-50’O’/100+50/37146020010012307801615510
4SR-60’OH’/50+60/4514602005012257851615590
4SR-75’OH’/50+75/5514602005012257851615590
4SR-75MM/16+75/5514601501611757601565650
4SR-75MM/20+75/551460150209907101395700
4SR-100’OH’/100+100/75146020010012808751700900
4SR-120NN/25+120/9014602002514008201815850
4SR-150’OO’/100+150/1101460200100143087518501100
Note: All dimensions are in millimeter (mm).
Non-clog Series Pumps
Options
  • Option of pump with dry motor as well as oil filled motor.
  • Option of pumps with inbuilt agitator arrangement.
  • Pumps can be offered for 60 Hz.
  • Option of pumps with cooling jacket.
  • Option of pumps with Spiral cutting plate.
  • Guiderail / Fastout arrangement Upto 20 mtr pit depth.
  • Veriety of MOCs to choose from.
Recommendations
  • Always flush the pump with clean water after use.
  • In case of maintenance always use genuine spares.
  • Ensure use of proper control panel for proper safety & running of dewatering pumps.
  • Always ensure that pump is properly earth.
Waste Water Series Pumps
Features
Impeller -Choice of impeller-Vortex,Radial ,Channel to cater different kind of soilid handling applications.Suitable for handling solids from MM to 50 mm
Motor – Highly efficient dry as well as wet motors with built- in protections against temperature rise.motor capable to withstand wide voltage.
Shaft – heavy duty Shaft to avoid feflection while pumping solids.
Mechanical Seals -Mechanical seals fitted in independent chambers, not exposedto pumpage liquid and devoide of discharge pressure.
Bearing– Heavy duty ball bearing used at top and bottom ends to balance adverse load.
Cable Sealing – Special leak proof cable sealing arrangement,to avoid ingress of water through cable.no need to open motor for changing cable.cable.
Float switch – Pumps up to 2HP can also be provided in single phase and with built -in Float arrangement.
Applications
  • CAR Parking areas
  • hotel & hospitals.
  • Pharmaceutical plants
  • Treated water from ETP/STP
  • CAR Parking areas
  • Cable Trench pits
  • Packeged sewage system.
Waste Water Series Pumps
Tech. Specifications*
Rating:Up to 100 HP
RPM:2900
Frequency:50 HZ
Supply:Three phase- 415 V
Starting:DOL
Motor:Wet type / Dry type
Process Data
Liquid temperature:Max 40° C
Liquid Density:Max 1100 kg/m3
Suitable for liquid pH:6 to 8
Stainer Hole Size:Up to 50 mm
Materials*
Impeller:CA – 15, CF8, CF8M,various grades of Cl
Shaft:AISI-410, SS-304, SS-316
Difusser:Various grades of CI/ SS
Wear plate:Various grades of CI/ SS
Mech. SealSic v/s Sic, Tc v/s Tc
Waste Water Series Pumps
Pump ModelHP/KWPhaseRPMOUTLET / DN SIZESOLID PASSAGEMINIMUM SUBMERGENCE (Approx.)WIDTH / OUTER DIA (Approx.)HEIGHT (Approx.)Net Weight (In Kg) (Approx.)
50MW S 08 351.0/0.75Single2900503533527045024.5
50MW T 08 351.0/0.75Three2900503533527045024.5
50MW S 08 501.0/0.75Single2900505036024048025.5
50MW T 08 501.0/0.75Three2900505036024048025.5
50MW S 11 351.5/1.1Single2900503533527045025
50MW T 11 351.5/1.1Three2900503533527045025
50MW S 11 501.5/1.1Single2900505036024048026
50MW T 11 501.5/1.1Three2900505036024048026
50MW S 15 352.0/1.5Single2900503533527047026
50MW T 15 352.0/1.5Three2900503533527047026
50MW S 15 502.0/1.5Single2900505038024049528
50MW T 15 502.0/1.5Three2900505038024049528
WP-03D/353.0/2.2Three2820803550033560063
WP-05D/355.0/3.7Three2830803550033560067
WR-03LM/203.0/2.2Three2820502049025058555
WV-03LL/403.0/2.2Three2820504047034056052
WV-05LL/405.0/3.7Three2830504047034056057
WP-07E/407.5/5.5Three285010040535415630120
WP-10E/4010/7.5Three285010040585415680140
WP-10D/4010/7.5Three28508040585335675125
WP-12E/4012.5/9.3Three286010040585415680145
WP-15E/1715/11Three287010017600475725170
WP-20E/2020/15Three288010020600475820190
WP-20H/4020/15Three293080409104301110270
WP-25H/4025/18.5Three293080409104301110300
WP-25EE/1025/18.5Three2890100107754201090253
WP-30H/4030/22Three293080409104301110310
WP-35EE/1035/26.1Three2890100108054201120260
WP-35H/4035/26.1Three293580409104301110330
WP-40H/4040/30Three2955804010104301210410
WP-50H/4050/37Three2960804010104301210510
WR-50HH/2050/37Three29008020880510995375
WP-60H/4060/45Three2960804011804301440565
WP-75H/4075/55Three2965804011804301440650
WP-100H/40100/75Three2965804012404301500750
4WC-10410/7.5Three1455100NA8504801055235
4WC-15415/11Three1455100NA9504801155268
4WC-20420/15Three1455100NA9504801155275
Waste Water Series Pumps
Options
  • Option of pumps with cooling jacket.
  • Option of pumps with inbuilt Cutter/Spiral cutting plate.
  • Guiderail / Fastout arrangement Upto 20 mtr pit depth.
  • Veriety of MOCs to choose from.
  • Choice of casing and impeller to suit specific solid handling applications.
Recommendations
  • Always flush the pump with clean water after use.
  • In case of maintenance always use genuine spares.
  • Ensure use of proper control panel for proper safety & running of dewatering pumps.
  • Always ensure that pump is properly earth.
Vertical Wet Pit Series Pumps
Features
Impeller -Specially deisgned impeller with wide passages that can pass solids up to 63 mm.
Motor – Vertical Flange Mounted TEFC motor. Can be FLP or Non FLP type
Shaft – Extra heavy duty SS Shaft, capablee to withstand adverse load
Bearing– Heavy duty grease lubricated ball bearing used at Top, Bottom & Intermidiate end of the shaft
Column Length – Pumps can be designed for column length of minimum 0.5 m to 6 mtrs
Casing – Specially designed casing assisting in free flow of liquids & solids, minimising the adverse load on pump
Applications
  • Municipal Waste, Raw & Un-Screened Sewage
  • Industrial Wastes & Effluents
  • Pharmaceutical, Textile & Tanning Plants
  • Municipal Sewer pumps
  • Effluent Treatment And Sewage Treatment Plants
  • Ro Reject / Desalination Projects
  • Chemical Handling Plants & Many More….
Vertical Wet Pit Series Pumps
 Tech. Specifications*
Rating:Up to 100 HP
RPM:1450 / 2900
Frequency:50 HZ
Supply:Three phase- 415 V
Motor:FLP / Non FLP
Process Data
Liquid temperature:Max 40° C
Liquid Density:Max 1100 kg/m3
Suitable for liquid pH:6 to 8
Stainer Hole Size:Up to 63 mm
Materials*
Impeller:Various grades of CI/ SS
Shaft:AISI-410, SS-304, SS-316
Casing:Various grades of CI/ SS
Column Pipe:Various grades of MS/ SS
Discharge  PipeVarious grades of MS/ SS
Vertical Wet Pit Series Pumps
Pump ModelHP/KWRPMOUTLET / DN SIZESOLID PASSAGEMINIMUM SUBMERGENCE (Approx.)WIDTH OF PUMPHeight of the PumpNet Weight (In Kg) (Approx.)
ES-505.0/3.7147050SHALL VARY AS PER SITE CONDITIONSSHALL VARY AS PER SITE CONDITIONS550SHALL VARY AS PER SITE CONDITIONSSHALL VARY AS PER SITE CONDITIONS
ES-507.5/5.5147050550
ES-5010/7.5147050550
ES-657.5/5.5147065615
ES-6510/7.5147065615
ES-6512.5/9.3147065615
ES-6515/11147065615
ES-65H20/15147065715
ES-65H25/18.5147065715
ES-65H30/22147065715
ES-8010/7.5147080615
ES-8012.5/9.3147080615
ES-80H15/11147080685
ES-80H20/15147080685
ES-100J20/151470100835
ES-100J25/18.51470100835
ES-100J30/221470100835
ES-100J35/26.11470100835
ES-100J40/301470100835
ES-100JH50/371470100870
ES-100JH60/451470100870
ES-100JH75/551470100870
ES-150M50/3714701501030
ES-150M60/4514701501030
ES-150M75/5514701501030
ES-150M100/7514701501030
ES-150MH75/5514701501060
ES-150MH100/7514701501060
ES-200’OO’75/5514702001250
ES-200’OO’100/7514702001250
Note: All dimensions are in millimeter (mm).
Vertical Wet Pit Series Pumps
Optoions
  • Pumps can be offerred for liquid temparature of 90◦C
  • Pump can be offerred for Hazardos areas as well
  • Pumps can be offered for 60 Hz.
  • Veriety of MOCs to choose from.
Recommendations
  • Always flush the pump with clean water after use.
  • In case of maintenance always use genuine spares.
  • Ensure use of proper control panel for proper safety & running of dewatering pumps.
  • Always ensure that pump is properly earth.

Industries & Clientele

Watch Video

Non Clog and Wastewater Pumps

Non-clog submersible pumps are ones which have an open or semi-open impeller that allows clogs, rags or suspended particles to be pumped along with the fluid. A cutter is required before the impeller vane to shred the clogs, rags or other suspended particles.

Non-clog Pumps are used for a variety of applications such as Raw & unscreened Sewage, Industrial wastes & effluents, Municipal Sewer Lines, Tailing ponds, Sewage treatment plants, Effluent Treatment Plants, Pharmaceutical & textile units & many more similar applications.

Your submersible pump may not be working owing to various reasons. Please check the manufacturers troubleshooting guide, consult a trained mechanic or a customer service representative. The troubleshooting guide is available in Operation & Maintenance Manual.

The minimum level of submergence for a submersible pump depends on the type of service and the load the motor is subjected to. For continuous service, the pump must be completely submerged in the pumped fluid; for intermittent service, the pump also works when partially submerged (up to its minimum submergence level) but it must be allowed to rest for reasonable periods to prevent the motor from overheating.
Some of our models are fitted with a special cooling casing so they can operate continuously even when partially immersed.

During operation, a pump motor can face overload. Knowing the most frequent causes of overload can help prevent malfunctions. The main reasons for overload can be: the impeller is blocked by foreign particles, the mechanical parts block due to excessive stopping times, the density of the liquid is greater than the maximum permitted density etc.. If you have any doubts, contact your dealer or specialized Darling Pump maintenance technician.

Connect With Us